Implications of Grid-Forming Inverter Parameters on Disturbance Localization and ControllabilityMatt Baughman, Marena Trujillo, Bri-Mathias Hodge et al.
The shift from traditional synchronous generator (SG) based power generation to generation driven by power electronic devices introduces new dynamic phenomena and considerations for the control of large-scale power systems. In this paper, two aspects of all-inverter power systems are investigated: greater localization of system disturbance response and greater system controllability. The prevalence of both of these aspects are shown to be related to the lower effective inertia of inverters and have implications for future widearea control system design. Greater disturbance localization implies the need for feedback measurement placement close to generator nodes to properly reject disturbances in the system while increased system controllability implies that widearea control systems should preferentially actuate inverters to most efficiently control the system. This investigation utilizes reduced-order linear time-invariant models of both SGs and inverters that are shown to capture the frequency dynamics of interest in both all-SG and all-inverter systems, allowing for the efficient use of both frequency and time domain analysis methods.
5.9SYJun 14
Nodal Frequency Stability-Constrained UC & ED for Renewable-Dominated Power SystemsMarena Trujillo, David Cole, Bri-Mathias Hodge
In modern power systems with high shares of renewable, inverter-based resources (IBRs), frequency stability becomes more complex due to the fast dynamics of IBRs and frequency trajectories that vary significantly from bus to bus. In this paper, we present an optimization framework for unit commitment and economic dispatch with endogenous frequency stability constraints at each bus. Two approaches for mitigating excessively low instantaneous frequency values in the event of the largest generator contingency are proposed: 1) by introducing a constraint requiring more thermal generation, and 2) by constraining the maximum power output of the generator that had the largest power output in the incumbent solution. Both approaches proved effective in eliminating dispatch scenarios that resulted in instantaneous frequencies below 58 Hz, while the second approach minimized the difference in production cost values from the non-stability-constrained case. Overall, the results indicate that the proposed optimization framework is a more effective alternative to frequency stability-constrained unit commitment and economic dispatch (UC & ED) than those based on the center-of-inertia (COI) principle.