Sairaj V. Dhople

SY
h-index36
7papers
733citations
Novelty42%
AI Score24

7 Papers

1.2SYJan 20, 2016
Uncovering Droop Control Laws Embedded Within the Nonlinear Dynamics of Van der Pol Oscillators

Mohit Sinha, Florian Dorfler, Brian B. Johnson et al.

This paper examines the dynamics of power-electronic inverters in islanded microgrids that are controlled to emulate the dynamics of Van der Pol oscillators. The general strategy of controlling inverters to emulate the behavior of nonlinear oscillators presents a compelling time-domain alternative to ubiquitous droop control methods which presume the existence of a quasi-stationary sinusoidal steady state and operate on phasor quantities. We present two main results in this work. First, by leveraging the method of periodic averaging, we demonstrate that droop laws are intrinsically embedded within a slower time scale in the nonlinear dynamics of Van der Pol oscillators. Second, we establish the global convergence of amplitude and phase dynamics in a resistive network interconnecting inverters controlled as Van der Pol oscillators. Furthermore, under a set of non-restrictive decoupling approximations, we derive sufficient conditions for local exponential stability of desirable equilibria of the linearized amplitude and phase dynamics.

1.2SYDec 21, 2015
Linear Approximations to AC Power Flow in Rectangular Coordinates

Sairaj V. Dhople, Swaroop S. Guggilam, Yu Christine Chen

This paper explores solutions to linearized powerflow equations with bus-voltage phasors represented in rectangular coordinates. The key idea is to solve for complex-valued perturbations around a nominal voltage profile from a set of linear equations that are obtained by neglecting quadratic terms in the original nonlinear power-flow equations. We prove that for lossless networks, the voltage profile where the real part of the perturbation is suppressed satisfies active-power balance in the original nonlinear system of equations. This result motivates the development of approximate solutions that improve over conventional DC power-flow approximations, since the model includes ZIP loads. For distribution networks that only contain ZIP loads in addition to a slack bus, we recover a linear relationship between the approximate voltage profile and the constant-current component of the loads and the nodal active and reactive-power injections.

1.2SYOct 27, 2018
Reduced-order Aggregate Dynamical Model for Wind Farms

Sanjana Vijayshankar, Victor Purba, Peter J. Seiler et al.

This paper presents an aggregate reduced-order model for a wind farm composed of identical parallel-connected Type-3 wind turbines. The model for individual turbines includes mechanical dynamics (arising from the turbine and doubly fed induction generator) and electrical dynamics (arising from the rotor-side and grid-side converters and associated filters). The proposed aggregate wind-farm model is structure preserving, in the sense that the parameters of the model are derived by scaling corresponding ones from the individual turbines. The aggregate model hence maps to an equivalent--albeit fictitious--wind turbine that captures the dynamics corresponding to the entire wind farm. The reduced-order model has obvious computational advantages, but more importantly, the presented analysis rigorously formalizes parametric scalings for aggregate wind-turbine models that have been applied with limited justification in prior works. Exhaustive numerical simulations validate the accuracy and computational benefits of the proposed reduced-order model.

30.2LGMay 22, 2020
FedPD: A Federated Learning Framework with Optimal Rates and Adaptivity to Non-IID Data

Xinwei Zhang, Mingyi Hong, Sairaj Dhople et al.

Federated Learning (FL) has become a popular paradigm for learning from distributed data. To effectively utilize data at different devices without moving them to the cloud, algorithms such as the Federated Averaging (FedAvg) have adopted a "computation then aggregation" (CTA) model, in which multiple local updates are performed using local data, before sending the local models to the cloud for aggregation. However, these schemes typically require strong assumptions, such as the local data are identically independent distributed (i.i.d), or the size of the local gradients are bounded. In this paper, we first explicitly characterize the behavior of the FedAvg algorithm, and show that without strong and unrealistic assumptions on the problem structure, the algorithm can behave erratically for non-convex problems (e.g., diverge to infinity). Aiming at designing FL algorithms that are provably fast and require as few assumptions as possible, we propose a new algorithm design strategy from the primal-dual optimization perspective. Our strategy yields a family of algorithms that take the same CTA model as existing algorithms, but they can deal with the non-convex objective, achieve the best possible optimization and communication complexity while being able to deal with both the full batch and mini-batch local computation models. Most importantly, the proposed algorithms are {\it communication efficient}, in the sense that the communication pattern can be adaptive to the level of heterogeneity among the local data. To the best of our knowledge, this is the first algorithmic framework for FL that achieves all the above properties.

1.2SYJun 7, 2017
Engineering Inertial and Primary-frequency Response for Distributed Energy Resources

Swaroop S. Guggilam, Changhong Zhao, Emiliano Dall'Anese et al.

We propose a framework to engineer synthetic-inertia and droop-control parameters for distributed energy resources (DERs) so that the system frequency in a network composed of DERs and synchronous generators conforms to prescribed transient and steady-state performance specifications. Our approach is grounded in a second-order lumped-parameter model that captures the dynamics of synchronous generators and frequency-responsive DERs endowed with inertial and droop control. A key feature of this reduced-order model is that its parameters can be related to those of the originating higher-order dynamical model. This allows one to systematically design the DER inertial and droop-control coefficients leveraging classical frequency-domain response characteristics of second-order systems. Time-domain simulations validate the accuracy of the model-reduction method and demonstrate how DER controllers can be designed to meet steady-state-regulation and transient-performance specifications.

1.2SYSep 25, 2015
Power Divider

Yu Christine Chen, Sairaj Dhople

This paper derives analytical closed-form expressions that uncover the contributions of nodal active- and reactive-power injections to the active- and reactive-power flows on transmission lines in an AC electrical network. Paying due homage to current- and voltage-divider laws that are similar in spirit, we baptize these as the power divider laws. Derived from a circuit-theoretic examination of AC power-flow expressions, the constitution of the power divider laws reflects the topology and voltage profile of the network. We demonstrate the utility of the power divider laws to the analysis of power networks by highlighting applications to transmission-network allocation, transmission-loss allocation, and identifying feasible injections while respecting line active-power flow set points.

1.2SYJun 15, 2015
Power Systems Without Fuel

Joshua Adam Taylor, Sairaj V. Dhople, Duncan S. Callaway

The finiteness of fossil fuels implies that future electric power systems may predominantly source energy from fuel-free renewable resources like wind and solar. Evidently, these power systems without fuel will be environmentally benign, sustainable, and subject to milder failure scenarios. Many of these advantages were projected decades ago with the definition of the soft energy path, which describes a future where all energy is provided by numerous small, simple, and diverse renewable sources. Here we provide a thorough investigation of power systems without fuel from technical and economic standpoints. The paper is organized by timescale and covers issues like the irrelevance of unit commitment in networks without large, fuel-based generators, the dubiousness of nodal pricing without fuel costs, and the need for new system-level models and control methods for semiconductor-based energy-conversion interfaces.