CVMay 30, 2018

Stochastic Deep Compressive Sensing for the Reconstruction of Diffusion Tensor Cardiac MRI

arXiv:1805.12064v156 citations
Originality Highly original
AI Analysis

This work addresses the challenge of prolonged and motion-prone DT-CMR scans for clinical applications, enabling faster and more reliable cardiac imaging.

The authors tackled the problem of long acquisition times and low signal-to-noise ratio in Diffusion Tensor Cardiac MRI by proposing a novel cascaded CNN-based compressive sensing technique, achieving high reconstruction fidelity and significant improvements over state-of-the-art methods in simulations.

Understanding the structure of the heart at the microscopic scale of cardiomyocytes and their aggregates provides new insights into the mechanisms of heart disease and enables the investigation of effective therapeutics. Diffusion Tensor Cardiac Magnetic Resonance (DT-CMR) is a unique non-invasive technique that can resolve the microscopic structure, organisation, and integrity of the myocardium without the need for exogenous contrast agents. However, this technique suffers from relatively low signal-to-noise ratio (SNR) and frequent signal loss due to respiratory and cardiac motion. Current DT-CMR techniques rely on acquiring and averaging multiple signal acquisitions to improve the SNR. Moreover, in order to mitigate the influence of respiratory movement, patients are required to perform many breath holds which results in prolonged acquisition durations (e.g., ~30 mins using the existing technology). In this study, we propose a novel cascaded Convolutional Neural Networks (CNN) based compressive sensing (CS) technique and explore its applicability to improve DT-CMR acquisitions. Our simulation based studies have achieved high reconstruction fidelity and good agreement between DT-CMR parameters obtained with the proposed reconstruction and fully sampled ground truth. When compared to other state-of-the-art methods, our proposed deep cascaded CNN method and its stochastic variation demonstrated significant improvements. To the best of our knowledge, this is the first study using deep CNN based CS for the DT-CMR reconstruction. In addition, with relatively straightforward modifications to the acquisition scheme, our method can easily be translated into a method for online, at-the-scanner reconstruction enabling the deployment of accelerated DT-CMR in various clinical applications.

Foundations

The foundational work for this paper's niche, ranked by how specifically the neighbourhood builds on it — not by global fame.

Your Notes