A Master-Follower Teleoperation System for Robotic Catheterization: Design, Characterization, and Tracking Control

arXiv:2407.13162v22 citationsh-index: 22
AI Analysis

This addresses the need for more precise and transparent robotic catheterization systems for surgeons and clinicians performing minimally invasive procedures, though it appears incremental in teleoperation technology.

The paper tackles the problem of improving teleoperated robotic catheterization systems by designing a three-degree-of-freedom master-follower system with a grip-insert-release mechanism to prevent catheter buckling and torsion. The results show path tracking errors ranging from 0.64 cm to 1.92 cm, indicating the system meets design targets but requires closed-loop controllers for hysteresis and nonlinearities.

Minimally invasive robotic surgery has gained significant attention over the past two decades. Telerobotic systems, combined with robot-mediated minimally invasive techniques, have enabled surgeons and clinicians to mitigate radiation exposure for medical staff and extend medical services to remote and hard-to-reach areas. To enhance these services, teleoperated robotic surgery systems incorporating master and follower devices should offer transparency, enabling surgeons and clinicians to remotely experience a force interaction similar to the one the follower device experiences with patients' bodies. This paper presents the design and development of a three-degree-of-freedom master-follower teleoperated system for robotic catheterization. To resemble manual intervention by clinicians, the follower device features a grip-insert-release mechanism to eliminate catheter buckling and torsion during operation. The bidirectionally navigable ablation catheter is statically characterized for force-interactive medical interventions. The system's performance is evaluated through approaching and open-loop path tracking over typical circular, infinity-like, and spiral paths. Path tracking errors are presented as mean Euclidean error (MEE) and mean absolute error (MAE). The MEE ranges from 0.64 cm (infinity-like path) to 1.53 cm (spiral path). The MAE also ranges from 0.81 cm (infinity-like path) to 1.92 cm (spiral path). The results indicate that while the system's precision and accuracy with an open-loop controller meet the design targets, closed-loop controllers are necessary to address the catheter's hysteresis and dead zone, and system nonlinearities.

Foundations

The foundational work for this paper's niche, ranked by how specifically the neighbourhood builds on it — not by global fame.

Your Notes