MED-PHCVNov 25, 2024

Improving Deformable Image Registration Accuracy through a Hybrid Similarity Metric and CycleGAN Based Auto-Segmentation

arXiv:2411.16992v13 citationsh-index: 14
Originality Incremental advance
AI Analysis

This work addresses anatomical changes in radiation therapy for cancer patients, offering incremental improvements by integrating AI-based methods into existing workflows.

The study tackled the problem of inaccurate deformable image registration (DIR) in adaptive radiation therapy by developing a hybrid similarity metric with CycleGAN-based auto-segmentation, resulting in improved accuracy such as prostate DSC increasing from 0.61 to 0.82 and 95% Hausdorff Distance decreasing from 11.75 mm to 4.86 mm.

Purpose: Deformable image registration (DIR) is critical in adaptive radiation therapy (ART) to account for anatomical changes. Conventional intensity-based DIR methods often fail when image intensities differ. This study evaluates a hybrid similarity metric combining intensity and structural information, leveraging CycleGAN-based intensity correction and auto-segmentation across three DIR workflows. Methods: A hybrid similarity metric combining a point-to-distance (PD) score and intensity similarity was implemented. Synthetic CT (sCT) images were generated using a 2D CycleGAN model trained on unpaired CT and CBCT images to enhance soft-tissue contrast. DIR workflows compared included: (1) traditional intensity-based (No PD), (2) auto-segmented contours on sCT (CycleGAN PD), and (3) expert manual contours (Expert PD). A 3D U-Net model trained on 56 images and validated on 14 cases segmented the prostate, bladder, and rectum. DIR accuracy was assessed using Dice Similarity Coefficient (DSC), 95% Hausdorff Distance (HD), and fiducial separation. Results: The hybrid metric improved DIR accuracy. For the prostate, DSC increased from 0.61+/-0.18 (No PD) to 0.82+/-0.13 (CycleGAN PD) and 0.89+/-0.05 (Expert PD), with reductions in 95% HD from 11.75 mm to 4.86 mm and 3.27 mm, respectively. Fiducial separation decreased from 8.95 mm to 4.07 mm (CycleGAN PD) and 4.11 mm (Expert PD) (p < 0.05). Improvements were also observed for the bladder and rectum. Conclusion: This study demonstrates that a hybrid similarity metric using CycleGAN-based auto-segmentation improves DIR accuracy, particularly for low-contrast CBCT images. These findings highlight the potential for integrating AI-based image correction and segmentation into ART workflows to enhance precision and streamline clinical processes.

Foundations

The foundational work for this paper's niche, ranked by how specifically the neighbourhood builds on it — not by global fame.

Your Notes